Revision as of 16:53, 13 May 2024 by MickShowCAD (talk | contribs) (Created page with "Simple ArtNet Setup by Mick Martin | Aug 29, 2012 | Knowledge Base This procedure sets up one 8 port XNet interface on Artnet. Computer Setup Set the IP address of the Ethernet port on the Artist computer to 2.0.0.1 and the sub-net mask to 255.0.0.0 Start Artist Right-click Navigator/Resources/Interface Manager/Artnet and select Properties In the Select Network combobox, select 2.0.0.1 Check Enable Click OK XNet Setup Connect the XNet interface Ethernet port with a...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Simple ArtNet Setup by Mick Martin | Aug 29, 2012 | Knowledge Base

This procedure sets up one 8 port XNet interface on Artnet.

Computer Setup


Set the IP address of the Ethernet port on the Artist computer to 2.0.0.1 and the sub-net mask to 255.0.0.0 Start Artist Right-click Navigator/Resources/Interface Manager/Artnet and select Properties In the Select Network combobox, select 2.0.0.1 Check Enable Click OK XNet Setup

Connect the XNet interface Ethernet port with a cross-over Cat5 cable to the Ethernet port on the computer you have set up Set the XNet address switches to x100 = 1, x10 = 3 and x1 = 0 which is an IP of address of 2.39.2.4 Set the XNet Universe and Subnet to 0. This is the default settings. Power up the XNet. Power off and on if the XNet was already powered. Artist Setup

Under Navigator/Resourses/Interface Manager/Artnet you should now see 2 new item. 2.39.2.4 and 2.39.2.5. Right-click on 2.39.2.4 and select Properties. Set the Outputs to 8 and Click OK. Right-click Navigator/Resources/Input Output Patch/DMX Outputs and select Properties. Set 8 universe to add Right-click Universe 1 and select Connect Select Artnet, Node – 2.39.2.4, Universe 1 Repeat for each of the added Universe 2 through 8 The system is now setup to drive 8 Universe.